Parameter listing and descriptions
321
ACH550-01 User's Manual
4 =
DI
4 – Enables the Interlock function, and assigns a digital input
(starting with
DI
4) to the interlock signal for each PFA relay. These
assignments are defined in the following table and depend on:
• the number of PFA relays [number of parameters 1401…1403 and
1410…1412 with value = 31 (PFA)]
• the Autochange function status (disabled if 8118
AUTOCHNG
INTERV
=
0.0, and otherwise enabled).
Code Description
Range
No. PFA
relays
Autochange disabled
(P 8118)
Autochange enabled
(P 8118)
0
DI
1…
DI
3: Free
DI
4: Speed Reg Motor
DI
5…
DI
6: Free
Not allowed
1
DI
1…
DI
3: Free
DI
4: Speed Reg Motor
DI
5: First PFA Relay
DI
6: Free
DI
1…
DI
3: Free
DI
4: First PFA Relay
DI
5…
DI
6: Free
2
DI
1…
DI
3: Free
DI
4: Speed Reg Motor
DI
5: First PFA Relay
DI
6: Second PFA Relay
DI
1…
DI
3: Free
DI
4: First PFA Relay
DI
5: Second PFA Relay
DI
6: Free
3
Not allowed
DI
1…
DI
3: Free
DI
4: First PFA Relay
DI
5: Second PFA Relay
DI
6: Third PFA Relay
4…6
Not allowed
Not allowed
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com