18 TYPE CONVERSION FUNCTIONS
18.34 Converting BCD to DINT
• A value input to (s) is within the range from 0H to 9999H (from 0 to 9 for each digit) for the WORD type data value and from
0H to 99999999H (from 0 to 9 for each digit) for the DWORD type data value.
• WORD or DWORD can be specified to (s). BOOL cannot be specified.
■
Operation result
1.
Function without EN/ENO
The following table lists the operation results.
2.
Function with EN/ENO
The following table lists the execution conditions and operation results.
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
• When (s) is WORD
• When (s) is DWORD
Operation result
(d)
No operation error occurred
Operation output value
An operation error occurred
Indefinite value
Execution condition
Operation result
EN
ENO
(d)
TRUE (Executes operation)
TRUE (Operation error did not occur)
Operation output value
FALSE (Operation error occurred)
Indefinite value
FALSE (Stops operation)
FALSE
Indefinite value
Error code
(SD0/SD8067)
Description
3401H
A value other than 0 to 9 exists in each digit of (s).
Error code
(SD0/SD8067)
Description
3401H
A value other than 0 to 9 exists in each digit of (s).
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......