398
8 APPLICATION INSTRUCTION
8.4 Structuring Instruction
Precautions
• If the branch pointer number of the BREAK instruction outside two nesting levels or more is specified, an operation error
occurs and the program execution stops when the BREAK instruction is executed.
Operation error
Error code
(SD0/SD8067)
Description
3340H
The branch pointer number outside two nesting levels or more is specified.
3342H
The BREAK(P) instructions are used other than between the FOR and NEXT instructions.
3380H
The destination pointer specified by (P) does not exist.
A pointer in other program file is specified in (P).