754
10 BUILT-IN ETHERNET FUNCTION INSTRUCTIONS
10.3 Predefined Protocol Support Function Instruction
*1 System: The CPU module stores the execution result of the instruction.
(s3)+1
Completion status
The completion status is stored upon completion of the instruction.
When two or more protocols are executed, the execution result of the protocol
executed last is stored.
• 0: Normal completion
• Other than 0: Error completion (error code)
System
(s3)+2
Execution protocol
number 1
Specify the number of the protocol to be executed first.
1 to 64
User
(s3)+3
Execution protocol
number 2
Specify the number of the protocol to be executed second.
0, 1 to 64
(s3)+4
Execution protocol
number 3
Specify the number of the protocol to be executed third.
0, 1 to 64
(s3)+5
Execution protocol
number 4
Specify the number of the protocol to be executed fourth.
0, 1 to 64
(s3)+6
Execution protocol
number 5
Specify the number of the protocol to be executed fifth.
0, 1 to 64
(s3)+7
Execution protocol
number 6
Specify the number of the protocol to be executed sixth.
0, 1 to 64
(s3)+8
Execution protocol
number 7
Specify the number of the protocol to be executed seventh.
0, 1 to 64
(s3)+9
Execution protocol
number 8
Specify the number of the protocol to be executed eighth.
0, 1 to 64
(s3)+10
Collation match
Receive packet
number 1
If receiving is included in the communication type of the protocol that has been
executed first, the receive packet number successful in collation match is stored.
If the communication type is "receive only", "0" is stored. If an error occurs
during execution of the first protocol, "0" is stored.
0, 1 to 16
System
(s3)+11
Collation match
Receive packet
number 2
If receiving is included in the communication type of the protocol that has been
executed second, the receive packet number successful in collation match is
stored. If the communication type is "receive only", "0" is stored. If an error
occurs during execution of the second protocol, "0" is stored. If the number of
protocols executed is less than 2, "0" is stored.
0, 1 to 16
(s3)+12
Collation match
Receive packet
number 3
If receiving is included in the communication type of the protocol that has been
executed third, the receive packet number successful in collation match is
stored. If the communication type is "receive only", "0" is stored. If an error
occurs during execution of the third protocol, "0" is stored. If the number of
protocols executed is less than 3, "0" is stored.
0, 1 to 16
(s3)+13
Collation match
Receive packet
number 4
If receiving is included in the communication type of the protocol that has been
executed fourth, the receive packet number successful in collation match is
stored. If the communication type is "receive only", "0" is stored. If an error
occurs during execution of the fourth protocol, "0" is stored. If the number of
protocols executed is less than 4, "0" is stored.
0, 1 to 16
(s3)+14
Collation match
Receive packet
number 5
If receiving is included in the communication type of the protocol that has been
executed fifth, the receive packet number successful in collation match is stored.
If the communication type is "receive only", "0" is stored. If an error occurs
during execution of the fifth protocol, "0" is stored. If the number of protocols
executed is less than 5, "0" is stored.
0, 1 to 16
(s3)+15
Collation match
Receive packet
number 6
If receiving is included in the communication type of the protocol that has been
executed sixth, the receive packet number successful in collation match is
stored. If the communication type is "receive only", "0" is stored. If an error
occurs during execution of the sixth protocol, "0" is stored. If the number of
protocols executed is less than 6, "0" is stored.
0, 1 to 16
(s3)+16
Collation match
Receive packet
number 7
If receiving is included in the communication type of the protocol that has been
executed seventh, the receive packet number successful in collation match is
stored. If the communication type is "receive only", "0" is stored. If an error
occurs during execution of the seventh protocol, "0" is stored. If the number of
protocols executed is less than 7, "0" is stored.
0, 1 to 16
(s3)+17
Collation match
Receive packet
number 8
If receiving is included in the communication type of the protocol that has been
executed eighth, the receive packet number successful in collation match is
stored. If the communication type is "receive only", "0" is stored. If an error
occurs during execution of the eighth protocol, "0" is stored. If the number of
protocols executed is less than 8, "0" is stored.
0, 1 to 16
Device
Item
Description
Setting range
Set by
*1
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......