8 APPLICATION INSTRUCTION
8.8 Character String Operation Instruction
435
8
Operation error
Error code
(SD0/SD8067)
Description
2820H
In the corresponding device range after the device specified by (s), "00H" does not exist.
In the corresponding device range after the device specified by (d), "00H" does not exist.
3406H
The whole concatenated character string cannot be stored in the devices from the device specified by (d) to the last device in the
corresponding device range.
The number of characters of the character string in the device specified by (s)+(d) exceeds 16383..
3405H
The character string specified by (s) has more than 16383 characters.
The character string specified by (d) has more than 16383 characters.