858
16 POSITIONING INSTRUCTION
16.1 Dedicated Instruction (Positioning Function)
Processing details
This instruction executes tables of multiple axes of one module simultaneously.
• For (n1), specify the head axis number for which pulses are output.
• For (n2), specify the table number that is executed with the axis (n1). When not executing the axis (n1), specify K0.
• For (n3), specify the table number that is executed with the axis (n1)+1. When not executing the axis (n1)+1, specify K0.
• For (n4), specify the table number that is executed with the axis (n1)+2. If axis (n1) + 2 is not executed or the axis number
of the high-speed pulse input/output module is specified to (n1), specify K0.
• For (n5), specify the table number that is executed with the axis (n1)+3. If axis (n1) + 3 is not executed or the axis number
of the high-speed pulse input/output module is specified to (n1), specify K0.
• For (d), specify the device of the instruction execution complete flag for each axis. Eight devices are occupied from (d), and
function as follows.
For details on the function and error code, refer to
MELSEC iQ-F FX5 User's Manual (Positioning Control - CPU module
built-in, High-speed pulse input/output module).
Precautions
Eight devices are occupied from the device specified in (d). Make sure that these devices are not used in other controls.
For other precautions, refer to
MELSEC iQ-F FX5 User's Manual (Positioning Control - CPU module built-in, High-speed
pulse input/output module).
Designation number
Axis numbers to be used
K1
Execute axis 1 to axis 4 (CPU module) simultaneously.
K5
Execute axis 5, axis 6 (high-speed pulse input/output module first module) simultaneously.
K7
Execute axis 7, axis 8 (high-speed pulse input/output module second module) simultaneously.
K9
Execute axis 9, axis 10 (high-speed pulse input/output module third module) simultaneously.
K11
Execute axis 11, axis 12 (high-speed pulse input/output module fourth module) simultaneously.
Device
Description
(d)
Instruction execution complete flag for the axis (n1)
(d)+1
Instruction execution abnormal end flag for the axis (n1)
(d)+2
Instruction execution complete flag for the axis (n1)+1
(d)+3
Instruction execution abnormal end flag for the axis (n1)+1
(d)+4
Instruction execution complete flag for the axis (n1)+2
(d)+5
Instruction execution abnormal end flag for the axis (n1)+2
(d)+6
Instruction execution complete flag for the axis (n1)+3
(d)+7
Instruction execution abnormal end flag for the axis (n1)+3
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......