13 CC-LINK IE FIELD NETWORK INSTRUCTION
13.2 Setting the station number to own station
803
13
Precautions
• The station number set by the G(P).UINI instruction is cleared when the FX5 CPU module is powered off and on or reset.
• The G(P).UINI can be executed on the intelligent device station with no station number setting.
• If the station number set by the G(P).UINI instruction is already used for another station, the instruction is completed with
an error. Set a unique station number. Note that such error cannot be detected before data link start (e.g. absence of the
master station).
Operation error
Error code
((s)+1)
Description
D000H to DFFFH
Refer to
MELSEC iQ-F FX5 User's Manual (CC-Link IE).