1034
25 CHARACTER STRING FUNCTIONS
25.6 Deleting Character String
■
Operation result
1.
Function without EN/ENO
The following table lists the operation results.
2.
Function with EN/ENO
The following table lists the execution conditions and operation results.
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
Operation result
(d)
No operation error occurred
Operation output value
An operation error occurred
Indefinite value
Execution condition
Operation result
EN
ENO
(d)
TRUE (Executes operation)
TRUE (Operation error did not occur)
Operation output value
FALSE (Operation error occurred)
Indefinite value
FALSE (Stops operation)
FALSE
Indefinite value
Error code
(SD0/SD8067)
Description
2820H
"00H" is not set to devices from the device number specified by (s) to the end device number of corresponding device.
3405H
The character strings specified by (s) have more than 255 characters.
The device value specified by (n1) is out of the valid range (0 to 255).
The device value specified by (n2) is out of the valid range (1 to 255).
(n1) exceeds the number of characters of a character string specified by (s).
(n2) exceeds the number of characters of a character string specified by (s).
3406H
The whole deleted character string cannot be stored in the devices from the device specified by (d) to the last device of the target device.
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......