Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-656
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
8
Error from welder 8.
Arc welding power source
error
(1)Check if the voltage detection wire is connected. Heck if the voltage
detection line or the short-circuit cap is connected to the CON7 of the
MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be
welded. Set the contact tip so as not to contact the work piece.
(3)Temporary power failure may have occurred.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
702
Sub code: Error No. from
welder.
Arc welding power source
error
(1)Check if the voltage detection wire is connected. Heck if the voltage
detection line or the short-circuit cap is connected to the CON7 of the
MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be
welded. Set the contact tip so as not to contact the work piece.
(3)Temporary power failure may have occurred.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4272
MOTOWELD SAFTY-
CIRCUIT ERROR
1
Error from welder 1.
Arc welding power source
error
Contact your Yaskawa representative.
2
Error from welder 2.
Arc welding power source
error
Contact your Yaskawa representative.
3
Error from welder 3.
Arc welding power source
error
Contact your Yaskawa representative.
4
Error from welder 4.
Arc welding power source
error
Contact your Yaskawa representative.
5
Error from welder 5.
Arc welding power source
error
Contact your Yaskawa representative.
6
Error from welder 6.
Arc welding power source
error
Contact your Yaskawa representative.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy