![YASKAWA Motoman DX200 Скачать руководство пользователя страница 1031](http://html2.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_maintenance-manual_30663671031.webp)
Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-810
2
The setting for width is
incorrect.
(1) For a rectangle, it is
incorrectly set as: width < 1.0,
width > sqrt (maximum
diameter2 - height2), or width
> maximum diameter.
(2) It is incorrectly set as:
width < 0, width > maximum
diameter -2 * radius.
Setting error
(1)Check the following settings.
∙
Setting of the width data
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3
The setting for height is
incorrect.
(1) For a rectangle, it is
incorrectly set as: height >
maximum diameter, height <
minimum diameter/2, or
height > sqrt (maximum
diameter
2
- width
2
).
Setting error
(1)Check the following settings.
∙
Setting of the height data
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4
The setting for the corner
radius is incorrect.
(1) For a rectangle, it is
incorrectly set as: corner
radius > width/2 or corner
radius > height/2.
Setting error
(1)Check the following settings.
∙
Setting of the corner radius
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy