Alar
m List
Alar
m Nu
mbe
r (4
00
0 to
4
9
99
)
Alarm List-845
Setting error
(1)Reset the alarm.
(2)Check the following settings.
?Check torque value
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4670
INSUFFICIENT NUM
OF SAMPLE DATA
Sub Code: Signifies the axis
in which the alarm occurred
Setting error
(1)Reset the alarm.
(2)Lengthen the measurement section.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4671
SAMPLE BUFFER
OVER FLOW
Sub Code: Signifies the axis
in which the alarm occurred
Setting error
(1)Reset the alarm.
(2)Shorten the measurement section.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4672
BASIC SPEED
UNREACHED
Sub Code: Signifies the axis
in which the alarm occurred
Setting error
(1)Reset the alarm.
(2)Increase the speed specification value of a measurement job or set
a small value for BASICV.
Or set a small value for BASICT, or lengthen the measurement section.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4673
MAX TRQ
UNDETECTED
Sub Code: Signifies the axis
in which the alarm occurred
Setting error
(1)Reset the alarm.
(2)Set a large value for the BASICT, and then check again.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4674
SETE ERROR
1
An attempt was made to set
tool for base/station-axis
position-type variable.
Setting error
(1)Check the following settings.
∙
Check the settings for jobs.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy