8
An attempt was made to
change the contents for the
job prohibited from being
edited.
Setting error
(1)Check the following settings.
∙
Setting of EDIT LOCK in JOB header screen
If the job is protected from editing, release the prohibition.
Software operation error
occurred
(1)Reset the alarm.
(2)If you edit this job, release the prohibition.
(3)If the error occurs again, delete the job where the alarm occurred.
(4)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(5)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
9
An attempt was made to
change the contents for the
job prohibited from being
edited.
Setting error
(1)Check the following settings.
∙
Setting of EDIT LOCK in JOB header screen
If the job is protected from editing, release the prohibition.
Software operation error
occurred
(1)Reset the alarm.
(2)If you edit this job, release the prohibition.
(3)If the error occurs again, delete the job where the alarm occurred.
(4)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(5)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy