Alar
m List
Alar
m Nu
mbe
r (4
00
0 to
4
9
99
)
Alarm List-799
4546
CANNOT EXECUTE
SYSTEM JOB
Sub Code: System number
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4547
PRIMITIVE ERROR
Sub Code: Error code
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4548
CANNOT OPERATE
SPECIFIED EVENT
Sub Code: System number
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4549
NOT EXECUTION OF
INIEVNT
Sub Code: System number
Setting error
(1)Check the following settings.
∙
Execute an INIEVNT instruction before executing an event related
instruction.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4550
CANNOT EXECUTE
INST(USER JOB)
Sub Code: System number
Setting error
(1)Check the following settings.
∙
This instruction cannot be executed in the system job. Correct the job
so that the instruction is executed in the user job.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4551
CANNOT MEASURE
TIP INSTALL COEF
Sub Code: Gun number
Setting error
(1)Check the following settings.
∙
Execute the "SVGUNCL TWC-AE", and then execute the "SVGUNCL
TWC=BE".
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4565
SOFTWARE
UNMATCH
1
The multi-layer welding
function is not used.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy