![YASKAWA Motoman DX200 Скачать руководство пользователя страница 1059](http://html2.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_maintenance-manual_30663671059.webp)
Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-838
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3
An attempt was made to
disconnect a control group
other than the occupation
control group when executing
a PSTART instruction.
Setting error
(1)Check the following settings.
∙
Check the settings for PSTART instruction.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4641
CANNOT EXECUTE
JOB
(SEPARATE GRP)
Sub Code: The disconnected
control group used by a move
instruction
Setting error
(1)Check the following settings.
∙
Correct the teaching so that the control group disconnected by itself is
not to operate for move instruction of own system.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4644
SPOT WELDER I/F
ERROR (ASW)
8
The controller could not send
an instruction to the welder
because the welder was busy
in processing.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state
of the following cables and connectors.
∙
DENGENSHA welding I/F board
∙
NADEX DeviceNet cable
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
9
Welding current error at
welding is completed
successfully.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
10
Abnormal code error at
welding is completed
successfully.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy