![YASKAWA Motoman DX200 Скачать руководство пользователя страница 635](http://html2.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_maintenance-manual_3066367635.webp)
Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-414
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4010
MEMORY ERROR
(COM-ARC COND
FILE)
Sub Code: Page number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the COM-ARC condition file in
maintenance mode, and then load the COM-ARC condition file saved
in the external memory device.
YCP21 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
YIF01 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4012
MEMORY ERROR
(LINK SERVOFLOAT)
Sub Code: Condition file
number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the link servo float condition file
in maintenance mode, and then load the link servo float condition file
saved in the external memory device.
YCP21 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
YIF01 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy