![YASKAWA Motoman DX200 Скачать руководство пользователя страница 634](http://html2.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_maintenance-manual_3066367634.webp)
Alar
m List
Alar
m Nu
mbe
r (4
00
0 to
4
9
99
)
Alarm List-413
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4008
MEMORY ERROR
(ARC END COND
FILE)
Sub Code: Page number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the arc end condition file in
maintenance mode, and then load the arc end condition file saved in
the external memory device.
YCP21 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
YIF01 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4009
MEMORY ERROR
(ARC AUX COND
FILE)
Sub Code: Page number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the arc auxiliary condition file in
maintenance mode, and then load the arc auxiliary condition file saved
in the external memory device.
YCP21 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
YIF01 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy