![YASKAWA Motoman DX200 Скачать руководство пользователя страница 674](http://html2.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_maintenance-manual_3066367674.webp)
Alar
m List
Alar
m Nu
mbe
r (4
00
0 to
4
9
99
)
Alarm List-453
18
Sub task to be set PSTART
has been already executed.
Setting error
(1)Reset the alarm.
(2)Check the following settings.
∙
The subtask is completed by the PWAIT instruction.
∙
The execution timing for start command
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4104
WRONG EXECUTION
OF LOAD INST
Sub Code1 to 245: Signifies
the data transmission error.
Setting error
* Refer to the instruction manual for Data Transmission Function for
details.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4105
WRONG EXECUTION
OF SAVE INST
Sub Code1 to 245: Signifies
the data transmission error.
Setting error
* Refer to the instruction manual for Data Transmission Function for
details.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4106
WRONG EXECUTION
OF DELETE INST
Sub Code1 to 245: Signifies
the data transmission error.
Setting error
* Refer to the instruction manual for Data Transmission Function for
details.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4107
OUT OF RANGE
(ABSO DATA)
Sub Code: Signifies the axis
in which the alarm occurred
Setting error
(1)Reset the alarm.
(2)Check the following settings.
∙
Move the manipulator or station to the zero position by the axis
operation and check the home position alignment marks (the arrow).
Blown fuse
If AL1962 "EAXA21 board failure" occurred simultaneously with this
alarm,
Replace the fuse(F1) in the EAXA21 board.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy