Alar
m List
Alar
m Nu
mbe
r (4
00
0 to
4
9
99
)
Alarm List-913
18
CIP Safety communication
was not established to the
default time.(Waiting for
TUNID configuration)
Software configuration
error occurred
(1)Reset the alarm.
(2)If the alarm occurs again, please carry out the following according to
a manual.
- Set up TUNID (combination data of an IP address and Safety
Network Number) using RSNetWorx for EtherNet/IP (setting tool by
Rockwell).
Software operation error
occurred
(1)Reset the alarm.
(2)If the alarm occurs again, please re-power on the safety PLC and
the robot controller.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, please check the connection or insertion
state of cables connected to the "CN104 connector of YCP21 board"
and safety PLC.
YSF21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF21 board.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4912
SAFETY FIELDBUS
COMM ERROR
1
Value of F_Dest_Add do not
match.
Setting error
(1)Reset the alarm.
(2)If the alarm occurs again, please check the following F-Parameter
settings.
∙
The value of F_Dest_Add that is set to the safety PLC and the
CP1616 board are the same.
YSF21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF21 board.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2
Value of F_Dest_Add is out of
range.
Setting error
(1)Reset the alarm.
(2)If the alarm occurs again, please check the following F-Parameter
settings.
∙
The value of F_Dest_Add that is set to the safety PLC and the
CP1616 board is in the range of 1-65534.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy