Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-682
54
Err054
Sub code[54**] shows the
error code of Fronius power
source
54:main error code
**:sub error code
Arc welding power source
error
Increase the bbc (burn-back control)
Switch off "Wire stick" in the set-up menu
After the end of welding, make sure that the wire does not collide with
the workpiece when the torch is retracted.
Confirm the Fronius's manual.
55
NoIGn
Sub code[55**] shows the
error code of Fronius power
source
55:main error code
**:sub error code
Arc welding power source
error
Set a lower Ito value
Keep the torch stand-off distance smaller before ignition.
Confirm the Fronius's manual.
56
Err056
Sub code[56**] shows the
error code of Fronius power
source
56:main error code
**:sub error code
Arc welding power source
error
Check how much wire is left on the spool
If necessary, change the spool.
Confirm the Fronius's manual.
57
NoGAS
Sub code[57**] shows the
error code of Fronius power
source
57:main error code
**:sub error code
Arc welding power source
error
Check what volume of gas is still available.
Confirm the Fronius's manual.
58
NoArc
Sub code[58**] shows the
error code of Fronius power
source
58:main error code
**:sub error code
Arc welding power source
error
Check the seam.
Confirm the Fronius's manual.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy