![YASKAWA Motoman DX200 Скачать руководство пользователя страница 366](http://html2.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_maintenance-manual_3066367366.webp)
Alar
m List
Alar
m Nu
mbe
r (0
00
0 to
0
9
99
)
Alarm List-159
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following connector.
∙
The PCI connector of the TOYOPUC board
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
23
An error was found in the
specified number of registers
for "Alarm/Error/Message" in
the system data of Allocation
setting information.
Setting error
(1)Check the following settings.
∙
Allocation configuration for the TOYOPUC
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following connector.
∙
The PCI connector of the TOYOPUC board
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
30
In the input side setting of
allocation configuration data,
the specified R-register start
No. for the TOYOPUC
exceeds the R-register limit.
Setting error
(1)Check the following settings.
∙
Allocation configuration for the TOYOPUC
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following connector.
∙
The PCI connector of the TOYOPUC board
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy