Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-514
Parts failure
Replace the fuse(F9) in the YFL unit.
Unit failure (YFL)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YFL unit.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4182
FUSE BLOWN
(EX-AXIS OT4-1)
Sub Code: Signifies the YFL
unit number in which the
alarm occurred.
Blown fuse
Replace the fuse(F10) in the YFL unit.
Short circuit or ground
fault
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check a short circuit or ground fault has
not occurred in overrun line of ex-axis.
Parts failure
Replace the fuse(F10) in the YFL unit.
Unit failure (YFL)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YFL unit.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4183
FUSE BLOWN
(BRAKE:1)
Sub Code: Signifies the YFL
unit number in which the
alarm occurred.
Blown fuse
Replace the fuse(F11) in the YFL unit.
Short circuit or ground
fault
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check a short circuit or ground fault has
not occurred in brake line.
Parts failure
Replace the fuse(F11) in the YFL unit.
Unit failure (YFL)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YFL unit.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4184
FUSE BLOWN
(BRAKE:2)
Sub Code: Signifies the YFL
unit number in which the
alarm occurred.
Blown fuse
Replace the fuse(F12) in the YFL unit.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy