![YASKAWA Motoman DX200 Скачать руководство пользователя страница 586](http://html2.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_maintenance-manual_3066367586.webp)
Alar
m List
Alar
m Nu
mbe
r (1
00
0 to
1
9
99
)
Alarm List-379
YSF22 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF22 board.
Other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
203
CPU2 of YSF21 board was
not able to detect connection
with YSF22 board in start up
process.
Connection failure
Check the connection of the MII cable between YSF21 board and
YSF22 board.
YSF21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF21 board.
YSF22 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF22 board.
Other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
204
CPU2 of YSF21 board
detected connection with CH1
of YSF22 board in start up
process.
Connection failure
Check the connection of the MII cable between YSF21 board and
YSF22 board.
YSF21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF21 board.
YSF22 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF22 board.
Other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
205
CPU2 of YSF21 board did not
detect a response from
YSF22 board within a time
limit.
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following boards.
Check the connection of the MII cable between YSF21 board(CN203)
and YSF22 board(CN250/CN251).
YSF21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF21 board.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause