Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-878
YFC22 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YFC22 board.
In a system where a plurality of YFC22 boards are connected, replace
the board, which is connected to the XIN signal on which the alarm
occurred.
Other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4746
M-SAF SAFETY
FENCE SIG. ERROR
Safety fence signal is
unmatched for a certain time.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state
of the following cables and connectors.
∙
YFC22
∙
YSF22-YFC22 cable
∙
Check connectors of the connected outside devices of SAFETY
FENCE signal line.
YSF21 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF21 board.
YSF22 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF22 board.
In a system where a plurality of YSF22 boards are connected, replace
the YSF22 board which is connected to the first EAXA21 board.
YFC22 board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YFC22 board.
In a system where a plurality of YFC22 boards are connected, replace
the board, which is connected to the XIN signal on which the alarm
occurred.
Other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy