Ala
rm L
ist
Ala
rm
Numb
er
(
1
00
0 to
19
99)
Alarm List-360
2
The servo float function was
used for the axis for which the
axis endless function was
enabled.
The servo float function
cannot be used for the axis
which the axis endless
function was enabled.
Setting error
Disable either the axis endless function or the servo float function of
corresponding axis.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3
The encoders manufactured
by Tamagawa Seiki Co., Ltd.
was used for the axis for
which the axis endless
function was enabled.
The encoders manufactured
by Tamagawa Seiki Co., Ltd.
cannot be used for the axis
which the axis endless
function was enabled.
Setting error
Disable the corresponding axis endless function.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4
The general servo function
was used for the axis for
which the axis endless
function was enabled.
The general servo function
cannot be used for the axis
which the axis endless
function was enabled.
Setting error
Disable the corresponding axis endless function.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).