background image

Hacousto Holland bv 

Industrieweg 87 

2651BC  Berkel & Rodenrijs 

 

4EVAC Compact 500 operation manual 

Author: 

DD 

 

 

 

Page 1 of 15 

  

 

 
 
  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SUMMARY 
This document is the operation manual for users of the Compact 500 Voice Evacuation System. It explains 

how to operate the Compact 500 and how to interpret indications. This operation manual is addressed to 

end users as well as technical personnel, such as service technicians. 
 
REVISION AND APPROVAL 

Rev. 

Date 

Nature of Changes 

Approved By 

02 

05-07-2017 

Minor corrections, typos 

DD 

03 

14-01-2018 

Backup amp test, bandwidth update  

DD 

04 

04-06-2020 

Corrections 

TvdH 

 

 

Содержание Compact 500

Страница 1: ...0 Voice Evacuation System It explains how to operate the Compact 500 and how to interpret indications This operation manual is addressed to end users as well as technical personnel such as service tec...

Страница 2: ...system 4 Network system 4 3 2 1 Global network G Net 4 3 2 2 Local network L Net 5 4 Front Panel 6 LED indicators 6 4 1 1 POWER 6 4 1 2 EVAC 6 4 1 3 FAULT 7 4 1 4 POWER SUPPLY 7 4 1 5 SYSTEM FAULT 7 4...

Страница 3: ...he Compact 500 is to provide public address functionalities such as background music public announcements or general paging Compact 500 is extremely scalable due to its network capabilities and create...

Страница 4: ...NCE and RESET input 8 x GPI 8 x GPO Up to 6 loudspeaker lines with EOL monitoring 100W or 200W maximum power per line 2 analog balanced audio inputs Integrated Fireman Microphone with priority Access...

Страница 5: ...500 operation manual Author DD Page 5 of 15 3 2 2 Local network L Net L Net daisy chain topology is dedicated for peripheral devices of the main unit such as remote microphone stations L Net is used t...

Страница 6: ...dicates the operating status of the C500 Continuous system is powered and ready Blinking fast system is booting not ready for full operation 4 1 2 EVAC Indicates that the system is in the Voice Alarm...

Страница 7: ...charger o Battery resistance too high o Temperature fault o Charger communication fault 4 1 5 SYSTEM FAULT Indicates system fault of the C500 main unit where The CPU or program execution is stopped or...

Страница 8: ...d by one of following audio signals Continuous LIVE EVAC Blinking slow EVAC Message 4 1 7 2 Yellow Indicates that the zone is transmitting an ALERT message and or is in fault state Continuous Zone fau...

Страница 9: ...ed in the configuration settings 4 2 4 RESET Press to clear your current zone selection 4 2 5 FUNCTION button Press and hold the FUNCTION button to enable Access level 2 In access level 2 you are able...

Страница 10: ...nel one by one forcing the backup amplifier to engage and take over the channel where the fault is simulated The sequence will be displayed on the front panel ZONE LEDs NOTE the backup amplifier test...

Страница 11: ...essage ALERT message SILENCE RESET fireman mic with PTT button Fireman microphone Integrated Fireman Mic with priority and electrical monitoring Power supply equipment Built in power supply system EN...

Страница 12: ...29 kg Housing material Steel ABS IP rating IP 30 Mounting Wall mounted box Network system Max number of devices in the network 255 Max number of zones 255 Max total system output power 102 kW Number...

Страница 13: ...Hacousto Holland bv Industrieweg 87 2651BC Berkel Rodenrijs 4EVAC Compact 500 operation manual Author DD Page 13 of 15 8 Marking...

Страница 14: ...Hacousto Holland bv Industrieweg 87 2651BC Berkel Rodenrijs 4EVAC Compact 500 operation manual Author DD Page 14 of 15...

Страница 15: ...651BC Berkel Rodenrijs 4EVAC Compact 500 operation manual Author DD Page 15 of 15 M A D E I N T H E N E T H E R L A N D S 4EVAC is a trade name of Hacousto Holland bv Industrieweg 87 2651BC Berkel Rod...

Отзывы: