Use only the transceivers and adapters that shipped with your instrument, or
those that are identified on the list of Viavi supported optics that shipped with your
instrument. The recommended optics are also available on your instrument by
selecting
Help > Recommended Optics
. Many of these transceivers and
adapters can be purchased from Viavi.
•
Verify that the transceiver, adapter (if applicable), and the connector on the instru-
ment support the same physical interface. For example, if you intend to connect a
CSAM to a 100G Ethernet circuit, verify that you are inserting a CFP transceiver
(or adapter) into the CFP2 port of the CSAM. If you inserted a CFP2 adapter,
verify that you are inserting the appropriate transceiver for the adapter (CFP4 or
QSFP28).
To insert a SFP/SFP+, XFP, QSFP+, or QSP28 transceiver
1
Obtain a transceiver from Viavi that supports the physical interface you intend to
test.
If you are not certain which interfaces a particular transceiver supports, refer to
the list of Viavi Recommended Optics.
If you can not locate the sheet, in most instances an online search using the
model number (printed on the transceiver label) will result in a number of hits
providing specifications for the transceiver.
2
After verifying that you have the correct transceiver for the interface, do the
following:
a
Position the instrument with the connector panel facing towards you.
b
Ensure that the bale-clasp latch on the transceiver is closed as illustrated in
. The bale-clasp latch handle should be on top of the transceiver
module.
c
With the identification label facing away from you, align the transceiver with
the connector cage, and then gently but firmly insert the transceiver until it is
seated securely (indicated by an audible click, or by feeling the transceiver
snap into place).
NOTE:
Details concerning the inserted transceiver used for the currently selected
application appear on the Interface setup tab.
Figure 38
Transceiver (SFP shown) with closed bail-clasp latch