Chapter 4
Basic Testing
Scheduling timed tests
T-BERD/MTS/SC Getting Started Guide
March 2018
22046537, Rev. 016
Page 131
Scheduling timed tests
When you setup a test, you can indicate that the test should run for a specific period of
time (Timed Tests), or you can schedule tests to begin at a specific time (Delayed-start
Timed Test).
To schedule a timed test
1
Using the Test menu, select a test application (see
“Step 1: Selecting a test appli-
2
Select the
Setup
soft key.
A setup screen with a series of tabs appears.
3
Select the Timed Test tab, and then select one of the following test types:
–
Timed Test
. If you want the test to start immediately and run for a specific interval of
time, select Timed Test, and then specify the duration for the test in the corresponding
fields.
–
Delayed-start Timed Test
. If you want the test to start at a specific time, and then run
for a specific interval of time, select Delayed-start Timed Test, specify the duration for
the test, and then specify the date and time you want the test to begin in the corre-
sponding fields.
4
In Timed Test Enable, select
ON
.
5
Specify the timed test duration in the fields provided. Use the up and down arrows
to increase or decrease the intervals, or select a field, and then select the keypad
icon to type in a value.
The test duration is specified. The test will run for the interval you specified when you
press START or Restart to begin your test.
Creating and printing reports
Use the Reports option on the Menu bar or the PRINT/EXPORT key on the front panel
of your unit to format, create, store, and print reports detailing the current setup and test
results. You can also optionally include screen shots in your reports.
NOTE: J-Connect
Do not run timed tests when using J-Connect to detect other Viavi test instru-
ments on a subnet. For details, see the
Ethernet and Fibre Channel Testing
Manual
that shipped with your instrument or upgrade.
NOTE:
Depending on the version of T-BERD
⁄
MTS 8000 base unit you have, the key
may be labeled PRINT or may be labeled EXPORT (on UIMv2).