Appendix A
Specifications
Jitter and Wander specifications
T-BERD/MTS/SC Getting Started Guide
March 2018
22046537, Rev. 016
Page 229
Modulation specifications
describes the modulation specifications for the electrical wander generator.
Error limits
The error limits conform to the requirements of
ITU-T Recommendation O.172 (04/
2005)
, with a modulation frequency accuracy of ± 0.1%.
Synchronization
When generating wander, the device must be synchronized with an external timing
source. For more details, see
Wander measurement
This section provides specifications for wander measurements.
Reference clock
lists the wander clock frequency and input level specifications.l
Measurement range
The upper limit of the wander frequency range is set by a first-order low-pass filter. The
sample rate is selected automatically to correspond with the selected low-pass filter.
lists the sample rates for various low pass filters.
Table 148
Modulation specifications
Item
Description
Jitter modulation signal
sinusoidal
Frequency range
10
μ
Hz to 100 MHz
Amplitude range at 155.52 Mbps
0.01 UI to 3600 UI
Table 149
Wander clock frequency and input level specifications
Permissible offset
± 1000 ppm
Wander transfer bandwidth
Driven by the low pass filter as specified in
.
Table 150
Sample rates for various low pass filters
Low pass filter/fc
Sample rate
0.1 Hz
1/s
10 Hz
30/s
20 Hz
60/s
100 Hz
1000/s