Setting Data
Detection Time (Common)
Set the time range to perform pressure failure detection.
Setting rangb is from 0.0 seconds to 29.9 seconds.
Failure detectionis carried out within the setting time range after
injection starts. Set starting time and ending time.
* In the case that completion time is “0.0” seconds,
&
*
Failure detection will not Be carried out..,.
Spec Range (Force)
Set the allowable range for Clamp pressure.
Setting range is from 0.0 tons - 60.0 tons.
W hen the loaded data in the molding graph (Clamppressure) exceeds
the range o f the basic graph +/- setting pressure, an error will occur and
the machine will stop.
Spec Range (Position)
Set the allowable range for Clamp position.
Setting range is from 0.00 mm - 100.00 mm.
W hen the loaded data in the molding graph (Clamp position) exceeds
the range o f the basic graph +/- setting position, an error will occur and
the machine will stop.
Spec Range (FM pressure)
-
«•«Л
«■
'*ij'
f
Set the allowable range for FM pressure.
Setting range is from 0.0 torr - 100.0 top*
W hen the loaded data in the molding graplr(FM pregsiire) exceeds the
range o f the basic graph +/- setting,pressure, an error will occur and the
machine will stop.
Time Range (Common)
Set the time range to perform failure detection.
Setting range is from 0.0 seconds to 4.9 seconds.
Operations of Touch-Sensitive Screen
“OK” button
Set the input data
“Cancel” button
To return to previous screen
8-60
TSWA
Содержание LCM1010
Страница 9: ...1 GENERAL INFORMATION LCM 1010 Instruction Manual TCWA...
Страница 86: ...LCM1010 Instruction Manual 5 PREPARATION TCWA 5 5...
Страница 111: ...6 OPERATION LCM 1010 Instruction Manual 6 22 TCWA...
Страница 174: ...LCM1010 Instruction Manual 2 SAFETY NOTE The f gure below is for use with four Press Modules Automatic T WA 2 39...
Страница 191: ...3 OUTLINE OF MACHINE LCM 1010 Instruction Manual 3 12 TSWA...
Страница 193: ...4 OPERATION SWITCHES AND BUTTONS LCM 1010 Instruction Manual T WA...
Страница 211: ...LCM1010 Instruction Manual 5 PREPARATION TSWA 5 5...
Страница 433: ...LCM 1010 Instruction Manual 4 INSTALLATION NOTE The figure below is for use with four Press modules Automatic TCWA 4 5...
Страница 480: ...4 INSTALLATION LCM1010 Instruction Manual Factory facility 1 n il 555l I 4 52 TCWA...
Страница 493: ...hoocividli Mi u r c rtoociviDLi piN mcuftoc u r m MMorum luivi iu iu instruction manual t w a...
Страница 528: ...APPEND APPENDIX 1 4 CHARGE NUMBERLIST TSWA APPENDI...
Страница 533: ...APPENt g APPENDIX 2 3 RedpeDataandConstantData TSWA APPENDI...
Страница 549: ...4...
Страница 551: ...P R E S S M O D U L E I...