Assert input A to operate using purely the Alternate Torque
Limits.
For
PWM torque limit control
, you can vary the active torque
limit linearly between the two torque limit settings by varying the
PWM duty cycle sent to Input A as follows:
•
Apply a 0% duty cycle (static low) to operate using purely
the "standard" Torque Limits.
•
Apply a 100% duty cycle (static high) to operate using
purely the Alternative Torque Limits.
•
Apply a duty cycle anywhere in between 0% and 100% to
create a linear combination of the two limits.
Additional Notes:
•
PWM input frequency range: 20 Hz up to 30 kHz.
•
If the PWM signal is off for 50mS or more the PWM input is
considered off.
•
Disable time = 10 mS.