C
L E A R
P
A T H
M C / S D
U
S E R
M
A N U A L
R
E V
.
3 . 0 9
1 0
T
EKNIC
,
I
NC
. T
EL
.
(585)
784-7454
C
HECK
DC
B
US
P
OWER
P
OLARITY
Damage Warning:
Reversing DC power polarity to your ClearPath
motor
will
permanently damage it.
Before you connect DC power to your ClearPath motor
, use a voltmeter
to verify that DC bus power is wired with the proper polarity. This is
particularly important if the cables were not made by Teknic.
For Teknic DC power cables (PN: CPM-CABLE-PWR-MS120), test DC
voltage at pins 3 and 2 as shown below (pin 3 is v+ and pin 2 is GND).
This should display a positive voltage reading.
2 (GND)
4
Teknic IPC-5
Power Supply
VDC
ClearPath
Voltage Range
24-75VDC
1
3 (V+)
Power Connector
(Molex 4-pin)
Polarity test from pin 3 (V+) to pin 2 (GND) shows a positive 75 volts
P
OWER
U
P
Y
OUR
C
LEAR
P
ATH
1.
Begin with the power supply turned off or unplugged.
2.
Connect the DC power cable from the power supply to the
ClearPath motor's 4 pin connector.
3.
Turn on (plug in) the power supply.
2
3
1
Power up sequence