HLFB
M
ODES
:
F
OR
C
LEAR
P
ATH
V
ELOCITY
M
ODES
Note: The following HLFB modes are available in Velocity operating
modes only.
.
Enable Input
Move Profile
Velocity vs Time
Velocity Error
Units: % of
Commanded Velocity
In-Range: Velocity
Range: +/- 3%
ASG-Velocity
ASG-Velocity
Latched
ASG-Velocity
w/Measured Torque
ASG-Velocity, Latched
w/Measured Torque
0
0
0
1
0
1
0
1
0
1
0
+3%
-3%
1
0
1
NOTE: PWM DUTY CYCLE VARIES WITH TORQUE
NOTE: PWM DUTY CYCLE VARIES WITH TORQUE
“At Target Velocity” Verify Time
PWM Active
Not in Range
In Range
v+
v-
HLFB Timing: HLFB output modes available only in ClearPath velocity op modes
ASG
(A
LL
S
YSTEMS
G
O
)
-
V
ELOCITY
In ASG-Velocity mode the HLFB output asserts (conducts) when the
motor is enabled, not shutdown, and is "At Target Velocity".
"At Target Velocity" occurs when the motor has settled within
±
X% of the
final target velocity, for at least Y milliseconds (where X and Y are user-
settable through the MSP software).
Note:
The HLFB output deasserts during periods of commanded
acceleration and deceleration (i.e., when the velocity command is
changing), or if the motor's actual position falls out of the
±
X% In-Range