C
L E A R
P
A T H
M C / S D
U
S E R
M
A N U A L
R
E V
.
3 . 0 9
1 5 2
T
EKNIC
,
I
NC
. T
EL
.
(585)
784-7454
S
TEP AND
D
IRECTION
T
IMING
The ClearPath Step Input is “positive edge-triggered”, so ClearPath
registers a step only when Input B sees the rising edge of a step input
pulse (i.e. an electrical transition from low to high). Refer to the diagram
below for details and important step and direction signal timing
requirements.
Note:
ClearPath can be configured to move one count for each step
received, or one count per [x steps] received, based on the Input
Resolution setting.
Step
Position
Direction
n
n-1
n-1
n
t
pw
t
ds
t
ds
t
dh
t
ds
Minimum time between direction change and step input change = 25 nS
t
pw
Minimum
step pulse width = 715 nS
t
dh
Minimum direction hold time = 1 uS
Steps register on
the rising edge
Note:
In this example, 1 step received at Input B = 1 count of rotation.
(Input B)
(Input A)
t
pw