C
L E A R
P
A T H
M C / S D
U
S E R
M
A N U A L
R
E V
.
3 . 0 9
3 5
T
EKNIC
,
I
NC
. T
EL
.
(585)
784-7454
B
ASIC
P
OWER
C
ONNECTION
(2
MOTORS
)
One or two motors can be connected directly to the IPC-3 or IPC-5 power
supply as shown below. To connect more than two motors, consider
chaining power or using the optional Power Hub board.
75VDC
(Bus In)
75VDC
(Bus In)
ClearPath Motors
I
PC-5
75VDC
Bus Supply
75VDC
Bus Out
AC Source
110/220VAC
Direct Connection
P
OWER
C
HAINING
(
MULTIPLE MOTORS
)
For applications with several ClearPath motors, chaining power from
motor to motor may be preferable. You will have to fabricate power cables
as shown below to chain power from motor to motor.
Power Supply
(IPC-5 shown)
ClearPath Motors
2. GND
1. V+
4. GND
3. V+
Power Connector Pinout
Connector Housing
4 pos.
Molex/39-03-9042 (black)
Terminals
16AWG
Molex/39-00-0078 (loose)
Molex/39-00-0077 (reel)
Crimp Tool
16-24 AWG
Molex/63819-0900
Terminal Extractor Tool
Molex/11-03-0044
Mating Parts
Cable Stock
2/16AWG (black)
Belden/9410
Note:
NEMA 34 motors are shown at left. NEMA 23 models have
4-pin and 8-pin connector positions swapped, but pinouts and
signal names are functionally identical for both motor sizes.
ClearPath Power Supply Connection