C
L E A R
P
A T H
M C / S D
U
S E R
M
A N U A L
R
E V
.
3 . 0 9
6 6
T
EKNIC
,
I
NC
. T
EL
.
(585)
784-7454
Zone Limits (Normal)
Use the "Zone Limits" torque feature to set up directional torque limits in
different user-defined position zones along an axis of travel. See example
below.
Note:
The ClearPath system
must be homed
to use Zone Limits.
In this zone, torque applied
in the “positive” (CCW) direction will
be limited to
10%
of peak torque.
In this zone, torque applied
in the “negative” (CW) direction will
be limited to
20%
of peak torque.
Main Torque Limit
applies in this section
0
20,000
80,000
100,000
Load
1
2
1
2
50,000
Zone Torque Limits ("Normal" Zone Move Done Style)