Precision Homing dialog in Homing Setup window
To calibrate ClearPath to your mechanics
, you only need to
complete one initial homing operation. Whenever you need to clear and
reset calibration, click the (+) button as shown in the above screenshot
and follow the prompts to clear the calibration.
Important:
Any time a motor is connected to new or different
mechanics, or is disassembled from its associated mechanics and
reassembled,
you must clear the Precision Homing calibration
data
to allow a new calibration to occur.
Manually clear the Precision Homing calibration data
by doing
one of the following:
•
Press the “Clear Calibration…” button.
•
Load a motor configuration file.
•
Run Auto-tune.
•
Reset the configuration to factory default settings. Once cleared,
re-calibration will occur on the very next homing operation.