C
L E A R
P
A T H
M C / S D
U
S E R
M
A N U A L
R
E V
.
3 . 0 9
5 2
T
EKNIC
,
I
NC
. T
EL
.
(585)
784-7454
Note:
The HLFB output deasserts while moving, or if the motor's actual
position falls out of the
±
X encoder count In-Range window.
ASG-P
OSITION
L
ATCHED
ASG-Position Latched works in the same way as ASG-Position except that
the HLFB output latches once asserted (conducting). The output remains
asserted until the motor is disabled, goes into a shutdown, or receives a
motion command.
Even if the motor is momentarily pushed "Out-of-Range" at the end of a
move, the HLFB will remain asserted (conducting).
ASG-P
OSITION
W
ITH
M
EASURED
T
ORQUE
ASG-Position with Measured Torque works in the same way as ASG-
Position except during commanded motion, the HLFB outputs a 45 Hz or
482 Hz (user selectable) PWM waveform that varies in duty cycle between
5% and 95% to indicate direction and magnitude of motor shaft torque as
follows:
•
5% duty cycle = 100% peak torque, CW direction
•
50% duty cycle = zero torque
•
95% duty cycle = 100% peak torque CCW direction.
ASG-P
OSITION
L
ATCHED
W
ITH
M
EASURED
T
ORQUE
ASG-Position Latched with Measured Torque is a combination of all the
previous ASG-Position modes. During commanded motion the HLFB
outputs a PWM waveform to indicate motor shaft torque. Once the motor
reaches "Move Done" at the target position, the HLFB output latches
(stays on) even if the motor is pushed "Out-of-Range" until it is disabled,
goes into a shutdown, or receives a motion command.