Advanced-control timers (TIM1)
RM0365
517/1080
DocID025202 Rev 7
Bits 31:24 Reserved, must be kept at reset value.
Bits 23:20
MMS2[3:0]
: Master mode selection 2
These bits allow the information to be sent to ADC for synchronization (TRGO2) to be
selected. The combination is as follows:
0000:
Reset
- the UG bit from the TIMx_EGR register is used as trigger output (TRGO2). If
the reset is generated by the trigger input (slave mode controller configured in reset mode),
the signal on TRGO2 is delayed compared to the actual reset.
0001:
Enable
- the Counter Enable signal CNT_EN is used as trigger output (TRGO2). It is
useful to start several timers at the same time or to control a window in which a slave timer is
enabled. The Counter Enable signal is generated by a logic OR between the CEN control bit
and the trigger input when configured in Gated mode. When the Counter Enable signal is
controlled by the trigger input, there is a delay on TRGO2, except if the Master/Slave mode
is selected (see the MSM bit description in TIMx_SMCR register).
0010:
Update
- the update event is selected as trigger output (TRGO2). For instance, a
master timer can then be used as a prescaler for a slave timer.
0011:
Compare pulse
- the trigger output sends a positive pulse when the CC1IF flag is to
be set (even if it was already high), as soon as a capture or compare match occurs
(TRGO2).
0100:
Compare
- OC1REF signal is used as trigger output (TRGO2)
0101:
Compare
- OC2REF signal is used as trigger output (TRGO2)
0110:
Compare
- OC3REF signal is used as trigger output (TRGO2)
0111:
Compare
- OC4REF signal is used as trigger output (TRGO2)
1000:
Compare
- OC5REF signal is used as trigger output (TRGO2)
1001:
Compare
- OC6REF signal is used as trigger output (TRGO2)
1010:
Compare Pulse
- OC4REF rising or falling edges generate pulses on TRGO2
1011:
Compare Pulse
- OC6REF rising or falling edges generate pulses on TRGO2
1100:
Compare Pulse
- OC4REF or OC6REF rising edges generate pulses on TRGO2
1101:
Compare Pulse
- OC4REF rising or OC6REF falling edges generate pulses on
TRGO2
1110:
Compare Pulse
- OC5REF or OC6REF rising edges generate pulses on TRGO2
1111:
Compare Pulse
- OC5REF rising or OC6REF falling edges generate pulses on
TRGO2
Note: The clock of the slave timer or ADC must be enabled prior to receive events from the
master timer, and must not be changed on-the-fly while triggers are received from the
master timer.
Bit 19 Reserved, must be kept at reset value.
Bit 18
OIS6
: Output Idle state 6 (OC6 output)
Refer to OIS1 bit
Bit 17 Reserved, must be kept at reset value.
Bit 16
OIS5
: Output Idle state 5 (OC5 output)
Refer to OIS1 bit
Bit 15 Reserved, must be kept at reset value.
Bit 14
OIS4
: Output Idle state 4 (OC4 output)
Refer to OIS1 bit
Bit 13
OIS3N
: Output Idle state 3 (OC3N output)
Refer to OIS1N bit
Bit 12
OIS3
: Output Idle state 3 (OC3 output)
Refer to OIS1 bit