Analog-to-digital converters (ADC)
RM0365
307/1080
DocID025202 Rev 7
Note:
The polarity of the regular trigger cannot be changed on-the-fly.
Note:
The polarity of the injected trigger can be anticipated and changed on-the-fly. Refer to
Section 15.3.21: Queue of context for injected conversions
.
The EXTSEL[3:0] and JEXTSEL[3:0] control bits select which out of 16 possible events can
trigger conversion for the regular and injected groups.
A regular group conversion can be interrupted by an injected trigger.
Note:
The regular trigger selection cannot be changed on-the-fly.
The injected trigger selection can be anticipated and changed on-the-fly. Refer to
Section 15.3.21: Queue of context for injected conversions on page 311
Each ADC master shares the same input triggers with its ADC slave as described in
.
Figure 61. Triggers are shared between ADC master & ADC slave
Table 86. Configuring the trigger polarity for injected external triggers
JEXTEN[1:0]
Source
00
Hardware Trigger with detection on the rising edge
01
Hardware Trigger with detection on the rising edge
10
Hardware Trigger with detection on the falling edge
11
Hardware Trigger with detection on both the rising and falling edges