![Sony MVS-3000 System Скачать руководство пользователя страница 224](http://html.mh-extra.com/html/sony/mvs-3000-system/mvs-3000-system_user-manual_400286224.webp)
224
Cross-Point Settings
Chapt
er 17
Cont
ro
l P
anel Se
tup
Set:
Deletes the signal currently assigned to the
selected button number and makes a new
assignment.
Insert:
Moves the signal currently assigned to the
selected button number to the next number, and
makes a new assignment.
When a button number above 121 is selected,
execution of “Insert” is impossible. If an [Insert]
execution attempts to change a signal assignment to a
button number above 121, the signal assigned to 120 is
automatically deleted while signal assignments to 121
and above are maintained.
To disable a button
Select the button you want to disable, and press [Inhibit].
To delete an assigned signal
Select the button for the signal you want to delete, and
press [Delete] in the <Xpt Assign> group.
Signal deletion is executed in accordance with the
selection in the <Assign> group, and the signal assigned to
the button number next to the selected button number
moves up one line.
When a button number above 121 is selected, execution of
[Delete] is impossible.
If [Delete] execution attempts to change a signal
assignment to a button number above 121, the move ends
when the signal assigned to 120 moves to 119, and the
signals assigned to numbers 121 and above are maintained.
Creating tables 1 to 14
When creating tables 1 to 14, in the same way as when
creating the main table, you can assign the same signal to
more than one button number, or delete currently assigned
signals. However, assignment of video and key
combinations is impossible.
1
In the Engineering Setup >Panel >Xpt Assign menu
(7322), press [Table Button Assign].
The Table Button Assign menu (7322.1) appears.
The table number appears on the upper left part of the
status area.
The left part of the status area shows the cross-point
button numbers, video and key pair numbers, video
signal source names and source numbers, and key
signal source names and source numbers. When the
shift button is pressed, the number column is
distinguished by color.
The right part shows the video and key pair numbers,
and the names of video signals and key signals set in
the main table.
The Table Button Assign menu also allows you to
access the Main, V/K Pair Assign menu and the Src
Name/Src Color menu.
2
Select the table number.
3
Select the button number.
4
Select the pair number.
5
Using the buttons in the <Button Assign> group,
assign the selected pair number to the button number
currently selected in table 1.
Set:
Deletes the signal currently assigned to the
selected button number and makes a new
assignment.
Insert:
Moves the signal currently assigned to the
selected button number to the next number, and
makes a new assignment.
(If a button number above 121 is selected, see “Notes”
in step
5
.
To disable a button
Select the button you want to disable, and press [Inhibit].
To delete an assigned signal
Select the button for the signal you want to delete, and
press [Delete] in the <Button Assign> group.
The signal assigned to the button number next to the
selected button number moves up one line.
(When a button number above 121 is selected, see “Notes”
in
“To delete an assigned signal” (
.
Returning the table to its default state
1
In the Engineering Setup >Panel >Xpt Assign >Main,
V/K Pair Assign menu (7322.5) or Engineering Setup
>Panel >Xpt Assign >Table Button Assign menu
(7322.1), press [Default Recall].
2
Check the message, then press [Yes].
Setting the cross-point button shift
operation
You can set the operation of the rightmost button in each
row of cross-point buttons.
In the <Xpt Shift Mode> group of the Engineering Setup
>Panel >Xpt Assign >Main, V/K Pair Assign menu
(7322.5) or Engineering Setup >Panel >Xpt Assign >Table
Notes
Notes
No.
Parameter
Adjustment
1
Table No
Selection of the table to be set