![Sony MVS-3000 System Скачать руководство пользователя страница 253](http://html.mh-extra.com/html/sony/mvs-3000-system/mvs-3000-system_user-manual_400286253.webp)
253
Settings Relating to Function Links
C
hap
te
r 1
8 S
w
itc
he
r S
etu
p
Making Link Table Settings
1
Open the Engineering Setup >Switcher >Link
>Internal Bus Link >Link Table Select menu (7336.3).
2
Select the link source and link destination files.
3
To confirm the selection, press [Link Src Set].
This links the link destination signal to the signal
selected as Main No.
To initialize the set source address
Press [Init Link Table].
Check the message, then press [Yes].
Linking Cross-Point Buttons and
GPI Output Ports
To link cross-point buttons or the [CUT] and [AUTO
TRANS] buttons in the cross-point control block, and GPI
output ports, use the following procedure.
1
Open the Engineering Setup >Switcher >Link >GPI
Link menu (7336.4).
2
Select the GPI output port.
3
Press [GPI Link Adjust].
The GPI Link Adjust menu (7336.5) appears.
4
Select the setting to apply. For each GPI port there can
be up to eight links.
5
In the <Video/Button> group, press [Select].
The selected video or button name is reflected in the
status area.
To clear a video/button name link
Make the selection to which the setting applies, then
press [Clear] in the <Video/Button> group.
6
To select for each bus whether the GPI link setting is
enabled or disabled, select the bus to which the setting
applies.
7
In the <Bus> group, select any of the following.
Enable:
Enables the GPI link setting for the selected
bus.
Disable:
Disables the GPI link setting for the selected
bus.
All Enable:
Enables the GPI link setting for all buses.
Setting the delay value
1
In the Engineering Setup >Switcher >Link >GPI Link
Adjust menu (7336.5), select the output port for which
you want to set the delay value, and the corresponding
delay value.
2
Press [Delay Set].
Setting the operation mode when selecting
M/E reentry inputs
When you select a re-entry signal in the cross-point control
block of an M/E block (upstream M/E block), the output of
the upstream M/E block is read in. You can set the system
so that when a GPI link is set for the cross-point selected
on the A bus
1)
of the upstream M/E block this triggers the
GPI output.
In the Engineering Setup >Switcher >Link >GPI Link
menu (7336.4), set [Re-Entry Enable] to On or Off.
When set to On, the GPI is executed upstream.
1) When the bus toggle is set to Off, the applicable bus depends on the
position of the fader lever.
• For re-entry, “upstream” applies to a single stage only.
• This setting is common to all GPI output ports.
• GPI output execution on the upstream M/E block is only
possible on buses for which GPI Link is set to “Enable”
in the GPI Link Adjust menu.
• GPI outputs are executed when reentry signals are
selected under the following conditions.
- When selected using buttons in cross-point control
block
- When selected by macro execution
- When selected on the AUX bus remote panel
Setting Links between M/E Banks
The operations for which you can link two M/E banks are
as follows.
• Transition execution (auto transition, cut, and fader lever
operation)
• Next transition selection
No.
Parameter
Adjustment
1
Link No
Link to which setting applies
3
Link Table
No
Link table selection
No.
Parameter
Adjustment
1
GPI Port
GPI output port to be configured
5
Delay
Delay value for the output port
Notes