![Sony MVS-3000 System Скачать руководство пользователя страница 240](http://html.mh-extra.com/html/sony/mvs-3000-system/mvs-3000-system_user-manual_400286240.webp)
240
Settings for Switcher Configuration
C
hap
te
r 1
8 S
w
itc
he
r S
etu
p
Chapter
18
Switcher Setup
Settings for Switcher
Configuration
Adjusting the Reference Phase
To adjust the switcher internal reference phase, in the
Engineering Setup >Switcher >Config menu (7331), set
the following parameter.
Specifying the Video Switching
Timing
1
In the Engineering Setup >Switcher >Config menu
(7331), press [Switching Timing].
The Switching Timing menu (7331.8) appears.
2
Select any of the following.
Any:
Not specified
Field 1:
Field 1
Field 2:
Field 2
When the signal format is set to 720P or 1080PsF, this
selection is not possible.
Setting the Operation Mode
In the <M/E Config> group of the Engineering Setup
>Switcher >Config menu (7331), select the operation
mode for each M/E or PGM/PST bank from the following.
•
Standard mode:
Fixes the output configuration for the
maximum of four outputs (Out1 to 4) as follows.
- Out1: Program output
- Out2: Preview output
- Out3: Clean output
- Out4: Key preview output
1)
•
Multi-program mode:
The M/E or P/P 4-system
outputs (Out1 to 4) can be assigned to one of the
following outputs (M/E Output Assign).
- Program outputs 1 to 4
- Preview output
- Key preview outputs 1 and 2
1)
- Clean output
Further, you can change the combination of signals from
which the program output is configured (PGM Config).
1) For the key preview output, you can select either video mode (background
and key) or key mode (key only), and select the background and key (K-
PVW Config).
When Multi Program mode is selected, two or more
transition type indication may light. It is also possible that
more than one “Transition Type” has been selected in the
Misc >Transition menu for each M/E.
Assigning the output of each bank in Multi
Program mode
When [Multi Program] is selected as the operation mode,
use the following procedure.
1
In the Engineering Setup >Switcher >Config menu
(7331), press [M/E Output Assign].
The M/E Output Assign menu (7331.1) appears.
2
On the list in the status area, select the bank output to
be assigned.
3
In the <M/E Output Assign> group, select the output
signal to be assigned.
Setting the output configuration for each
bank
When [Multi Program] is selected as the operation mode,
use the following procedure.
No.
Parameter
Adjustment
3
Phase
Switcher internal reference phase
Notes
Notes