Installing
3.3 Installing Power Module
Frequency inverters with Control Units CU230P-2 HVAC, CU230P-2 DP, CU230P-2 CAN
Operating Instructions, 01/2011, FW 4.4, A5E02430659B AD
31
3.3.1
Dimensions, hole drilling templates, minimum clearances, tightening torques
Note
For Power Modules up to 132 kW, degree of protection IP20, the CU230P-2 increases the
total inverter depth by 50 mm - and an additional 30 mm if you use an IOP.
Dimensions and drilling patterns for the PM230 Power Modules
&RROLQJ
DLU
'LVVLSDWHG
KHDW
G
G
F
F
E
'HSWK
:LGWK
'HSWK
D
+H
LJ
K
W
Figure 3-1
Drilling pattern for PM230
Table 3- 1
Dimensions for PM230, IP55
Dimensions (mm)
Clearances (mm)
Frame size
Height
Width
Depth
a
b
c
d
FSA
460
154
238
445
132
100
0
FSB
540
180
238
524
158
100
0
FSC
620
230
238
604
208
125
0
FSD
640
320
238
600
285
300
0
FSE
751
320
238
710
285
300
0
FSF
915
410
238
870
370
300
0
Fixing:
FSA/FSB: screws M4, 2.5 Nm,
FSC: screws M5, 2.5 Nm,
FSD/FSE/FSF: screws M8, 13 Nm