![Siemens RUGGEDCOM RX1510 Скачать руководство пользователя страница 711](http://html.mh-extra.com/html/siemens/ruggedcom-rx1510/ruggedcom-rx1510_user-manual_380706711.webp)
RUGGEDCOM ROX II
User Guide
Chapter 5
Setup and Configuration
Flushing Dynamic Hardware Routing Rules
679
Parameter
Description
the default zone of the device will be used. The canonical format for the zone index is the
numerical format
Defines the nexthop IP address. The matched unicast packet is sent to the identified
gateway.
Pkts/sec
Synopsis:
The gauge32 type represents a non-negative integer, which may increase or
decrease, but shall never exceed a maximum value, nor fall below a minimum value. The
maximum value cannot be greater than 2^32-1 (4294967295 decimal), and the minimum
value cannot be smaller than 0. The value of a gauge32 has its maximum value whenever
the information being modeled is greater than or equal to its maximum value, and has its
minimum value whenever the information being modeled is smaller than or equal to its
minimum value. If the information being modeled subsequently decreases below (increases
above) the maximum (minimum) value, the gauge32 also decreases (increases). In the
value set and its semantics, this type is equivalent to the Gauge32 type of the SMIv2.
Displays the statistical throughput of all packets matching the rule, in packets per second.
static
Whether the rule is static or dynamic. Static rules are configured as a result of management
activity. Dynamic rules are automatically learned by the device and can be unlearned
subject to aging time.
routing-action
Synopsis:
forward, exclude
The action applied to packets matching the rule:
• Forward: Perform a hardware acceleration.
• Exclude: Exclude from hardware acceleration and always pass matching packets to the
CPU for software routing.
status
Synopsis:
active, resolving, pending, excluding
Whether the rule is currently operational or not:
• Active: The rule is fully operational and can be applied, so hardware acceleration is
performed.
• Resolving: The rule is not operational yet due to some unresolved information, like the
Address Resolution Protocol (ARP) or gateway's MAC address in the MAC Address
Table. Hardware acceleration is not performed.
• Pending: there are not enough hardware resources to setup the rule and all its
dependencies. Hardware acceleration is not performed.
Section 5.31.6
Flushing Dynamic Hardware Routing Rules
Flushing dynamic hardware routing rules removed dynamic rules from the Routing Rules Summary table.
NOTE
Only dynamic rules can be flushed. Static rules, enabled by activating hardware acceleration, never
age out. For more information about enabling hardware acceleration, refer to
To flush dynamic hardware routing rules, do the following:
1. Navigate to
switch
»
layer3-switching
and click
flush-dynamic-rules
. The
Trigger Action
form appears.
Содержание RUGGEDCOM RX1510
Страница 32: ...RUGGEDCOM ROX II User Guide Preface Customer Support xxxii ...
Страница 44: ...RUGGEDCOM ROX II User Guide Chapter 1 Introduction User Permissions 12 ...
Страница 62: ...RUGGEDCOM ROX II User Guide Chapter 2 Using ROX II Using the Command Line Interface 30 ...
Страница 268: ...RUGGEDCOM ROX II User Guide Chapter 4 System Administration Deleting a Scheduled Job 236 ...
Страница 852: ...RUGGEDCOM ROX II User Guide Chapter 5 Setup and Configuration Enabling Disabling an LDP Interface 820 ...