Chapter 3
Device Management
RUGGEDCOM ROX II
User Guide
104
Resetting a Switched Ethernet Port
Section 3.18.7
Resetting a Switched Ethernet Port
To reset a switched Ethernet port, do the following:
1. Navigate to
interfaces
»
switch
»
{slot/port}
, where
{slot/port}
is the slot name and port number of the
switched Ethernet port.
2. Click
reset-port
in the menu. The
Trigger Action
form appears.
1
Figure 104: Trigger Action Form
1.
Perform Button
3. Click
Perform
.
Section 3.18.8
Testing Switched Ethernet Port Cables
Diagnostics can be performed on switched Ethernet port cables to assess their overall quality.
The following sections describe how to test and diagnose switched Ethernet port cables:
•
Section 3.18.8.1, “Running a Cable Diagnostic Test”
•
Section 3.18.8.2, “Viewing Cable Diagnostic Statistics”
•
Section 3.18.8.3, “Clearing Cable Diagnostic Statistics”
Section 3.18.8.1
Running a Cable Diagnostic Test
To run a cable diagnostic test on a specific port, do the following:
IMPORTANT!
When cable diagnostics are performed on a port, any established network link on the port will be
dropped and normal network traffic will not be able to pass through either the Port Under Test (PUT) or
the Partner Port. When the cable diagnostic test is done, the original network port settings for both the
PUT and the Partner Port are restored along with any established link.
1. Navigate to
interfaces
»
switch
»
{slot/port}
»
diagnostics
, where
{slot/port}
is the slot name and port
number of the switched Ethernet port.
Содержание RUGGEDCOM RX1510
Страница 32: ...RUGGEDCOM ROX II User Guide Preface Customer Support xxxii ...
Страница 44: ...RUGGEDCOM ROX II User Guide Chapter 1 Introduction User Permissions 12 ...
Страница 62: ...RUGGEDCOM ROX II User Guide Chapter 2 Using ROX II Using the Command Line Interface 30 ...
Страница 268: ...RUGGEDCOM ROX II User Guide Chapter 4 System Administration Deleting a Scheduled Job 236 ...
Страница 852: ...RUGGEDCOM ROX II User Guide Chapter 5 Setup and Configuration Enabling Disabling an LDP Interface 820 ...