![Siemens RUGGEDCOM RX1510 Скачать руководство пользователя страница 675](http://html.mh-extra.com/html/siemens/ruggedcom-rx1510/ruggedcom-rx1510_user-manual_380706675.webp)
RUGGEDCOM ROX II
User Guide
Chapter 5
Setup and Configuration
Configuring L2TPv3 Tunnels
643
1
2
3
4
5
6
7
Figure 753: Static L2TPv3 Tunnels Form
1.
Enabled Check Box
2.
Tunnel ID Field
3.
Remote Tunnel ID Field
4.
Local IP Field
5.
Local Port Field
6.
Remote IP
Field
7.
Remote Port Field
6. On the
Static L2TPv3 Tunnels
form, configure the following parameter(s) as required:
Parameter
Description
enabled
Default:
true
Enables/Disables the tunnel
tunnel-id
The local tunnel-id
remote-tunnel-id
Tunnel-id of remote tunnel endpoint
local-ip
Ip address of local interface
local-port
Local listening transport port for tunnel service
remote-ip
Ip address of remote tunnel endpoint
remote-port
The listening transport port of remote device for tunnel service
7. Navigate to
tunnel
»
l2tpv3
»
static
»
tunnel
»
{tunnel name}
»
session
and select
Add session
. The
Key Settings
form appears.
Содержание RUGGEDCOM RX1510
Страница 32: ...RUGGEDCOM ROX II User Guide Preface Customer Support xxxii ...
Страница 44: ...RUGGEDCOM ROX II User Guide Chapter 1 Introduction User Permissions 12 ...
Страница 62: ...RUGGEDCOM ROX II User Guide Chapter 2 Using ROX II Using the Command Line Interface 30 ...
Страница 268: ...RUGGEDCOM ROX II User Guide Chapter 4 System Administration Deleting a Scheduled Job 236 ...
Страница 852: ...RUGGEDCOM ROX II User Guide Chapter 5 Setup and Configuration Enabling Disabling an LDP Interface 820 ...