Copyright © Siemens AG 2016. All rights reserved
317
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
9
Break_Error_Mask
0h
r w
10
Overrun_Error_Mask
0h
r w
31dt11 <unused>
000000h r
Reserved, do not modify, read as zero.
Register:
UARTRIS
Address:
3Ch
Bits:
31dt0
Reset value:
0h
Attributes:
r(h)
Description:
Raw Interrupt Status Register
Gives the raw interrupt state (prior to masking) of the interrupt
Bit
Identifier
Reset
Attr.
Function / Description
0
RI_Modem_Int_Status
0h
rh
1
CTS_Modem_Int_Status
0h
rh
2
DCD_Modem_Int_Status
0h
rh
3
DSR_Modem_Int_Status
0h
rh
4
Rx_Int_Status
0h
rh
5
Tx_Int_Status
0h
rh
6
Rx_Timout_Int_Status
0h
rh
7
Framing_Error_Int_Status 0h
rh
8
Parity_Error_Int_Status
0h
rh
9
Break_Err_Int_Status
0h
rh
10
Overrun_Err_Int_Status
0h
rh
31dt11 <unused>
000000h r
Reserved, do not modify, read as zero.
Register:
UARTMIS
Address:
40h
Bits:
31dt0
Reset value:
0h
Attributes:
r(h)
Description:
Mask Interrupt Status Register
Gives the masked interrupt state (after masking) of the interrupt
Bit
Identifier
Reset
Attr.
Function / Description
0
RIMMIS
0h
rh ...RI Intr.
1
CTSMMIS
0h
rh ...CTS Intr.
2
DCDMMIS
0h
rh ...DCD Intr.
3
DSRMMIS
0h
rh ...DSR Intr.
4
RXMIS
0h
rh ...Receive Interrupt
5
TXMIS
0h
rh ...Transmit Interrupt