Copyright © Siemens AG 2016. All rights reserved
290
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Register:
TIM_1_PRESCALER_REG
Address:
24h
Bits:
31dt0
Reset value:
00000000h
Attributes: (r) (w)
Description:
Timer PRESCALER Register for Timer 1
Bit
Identifier
Reset
Attr.
Function / Description
7dt0 PRESCALER_VALUE
00h
r w Prescaler Value
31dt8 <reserved>
000000h not used
Register:
TIM_1_LOAD_REG
Address:
28h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer LOAD/RELOAD Register for Timer 1
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 LOAD_RELOAD_VALUE
00000000h r w Load/Reload value
Register:
TIM_1_COUNT_REG
Address:
2Ch
Bits:
31dt0
Reset value:
00000000h
Attributes: r
Description:
Timer COUNT Register for Timer 1
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 COUNTER_VALUE
00000000h r Counter Value
Register:
TIM_1_INT_EV_REG
Address:
30h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer INT_EVENT Register for Timer 1
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 INT_EVENT_VALUE
00000000h rh w Internal Event Value
Register:
TIM_1_EXT_EV_1_REG
Address:
34h
Bits:
31dt0
Reset value:
00000000h
Attributes: r w
Description:
Timer EXT_EVENT_1 Register for Timer 1
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 EXT_EVENT_1_VALUE
00000000h rh w External Event 1 Value
Register:
TIM_1_EXT_EV_2_REG
Address:
38h
Содержание ERTEC 200P
Страница 1: ...ERTEC 200P 2 Enhanced Real Time Ethernet Controller Manual ...
Страница 309: ...Copyright Siemens AG 2016 All rights reserved 309 ERTEC 200P 2 Manual Technical data subject to change Version 1 0 ...
Страница 492: ...Copyright Siemens AG 2016 All rights reserved 492 ERTEC 200P 2 Manual Technical data subject to change Version 1 0 ...