Copyright © Siemens AG 2016. All rights reserved
393
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
ICU (IRQ37) and PN-ICU 1
1: GPIO5 is inverted from the A-ICU
(IRQ37) and PN-ICU 1
6 INT_POLSEL_GPIO6
xh
r w
0: GPIO6 is not inverted from the A-
ICU (IRQ38) and PN-ICU 1
1: GPIO6 is inverted from the A-ICU
(IRQ38) and PN-ICU 1
7 INT_POLSEL_GPIO7
xh
r w
0: GPIO7 is not inverted from the A-
ICU (IRQ39) and PN-ICU 1
1: GPIO7 is inverted from the A-ICU
(IRQ39) and PN-ICU 1
8 INT_POLSEL_GPIO8
xh
r w
0: GPIO8 is not inverted from the A-
ICU (IRQ40)
1: GPIO8 is inverted from the A-ICU
(IRQ40)
9 INT_POLSEL_GPIO9
xh
r w
0: GPIO9 is not inverted from the A-
ICU (IRQ41)
1: GPIO9 is inverted from the A-ICU
(IRQ41)
10 INT_POLSEL_GPIO10
xh
r w
0: GPIO10 is not inverted from the A-
ICU (IRQ42)
1: GPIO10 is inverted from the A-ICU
(IRQ42)
11 INT_POLSEL_GPIO11
xh
r w
0: GPIO11 is not inverted from the A-
ICU (IRQ43)
1: GPIO11 is inverted from the A-ICU
(IRQ43)
12 INT_POLSEL_GPIO12
xh
r w
0: GPIO12 is not inverted from the A-
ICU (IRQ44)
1: GPIO12 is inverted from the A-ICU
(IRQ44)
13 INT_POLSEL_GPIO13
xh
r w
0: GPIO13 is not inverted from the A-
ICU (IRQ45)
1: GPIO13 is inverted from the A-ICU
(IRQ45)
14 INT_POLSEL_GPIO14
xh
r w
0: GPIO14 is not inverted from the A-
ICU (IRQ46)
1: GPIO14 is inverted from the A-ICU
(IRQ46)
15 INT_POLSEL_GPIO15
xh
r w
0: GPIO15 is not inverted from the A-
ICU (IRQ47)
1: GPIO15 is inverted from the A-ICU
(IRQ47)