Copyright © Siemens AG 2016. All rights reserved
225
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Enable
2dt2 RORIE
0h
r w
RORIE=Receive FIFO Overrun
Interrupt Enable
3dt3 LBM
0h
r w LBM=Loop Back Mode
4dt4 SSE
0h
r w
SSE=Synchronous Serial Port
Enable
5dt5 MS
0h
r w MS=master/slave mode select
6dt6 SOD
0h
r w
SOD=slave mode output disa-
ble
Register:
SSPDR
Address: 508h
Bits:
31dt0
Reset value:
0h
Attributes: rh
w
Description:
SSPDR
Bit
Identifier
Reset
Attr. Function / Description
15dt0 DATA
0h
rh w Data
Register:
SSPSR
Address: 50Ch
Bits:
31dt0
Reset value:
0h
Attributes: rh
Description:
SSPSR
Bit
Identifier
Reset
Attr. Function / Description
0dt0 TFE
0h
rh
TFE=Transmit FIFO empty
1dt1 TNF
0h
rh
TNF=Transmit FIFO not full
2dt2 RNE
0h
rh
RNE=Receive FIFO not empty
3dt3 RFF
0h
rh
RFF=Receive FIFO Full
4dt4 BSY
0h
rh
BSY=SSP Busy Flag
Register:
SSPCPSR
Address: 510h
Bits:
31dt0
Reset value:
0h
Attributes:
(r)(
h)
(w)
Description:
SSPCPSR
Bit
Identifier
Reset
Attr. Function / Description
7dt0 CPSDVSR
0h
rh w
CPSDVSR=Clock Prescale
divisor
31dt8 reserved
0h
Содержание ERTEC 200P
Страница 1: ...ERTEC 200P 2 Enhanced Real Time Ethernet Controller Manual ...
Страница 309: ...Copyright Siemens AG 2016 All rights reserved 309 ERTEC 200P 2 Manual Technical data subject to change Version 1 0 ...
Страница 492: ...Copyright Siemens AG 2016 All rights reserved 492 ERTEC 200P 2 Manual Technical data subject to change Version 1 0 ...